We have a complete range of calibrated and amplified products that measure relative humidity (RH).
Based on TE’s robust patented capacitive technology, these sensors provide accurate measurement of dew point and absolute humidity by combining relative humidity and temperature measurements.
Our sensors are qualified for the most demanding applications, including automotive, heavy truck, aerospace, and home appliances.
We offer a variety of output signals such as digital (Frequency, I2C) and analog voltage, as well as, customized and proprietary output signals including PWM, PDM, LIN and CAN.
Humidity and Temperature (NTC) Components
Package |
Through-hole TO39 with side opening plastic cap
|
DFN type
|
DFN type
|
Type |
Capacitive humidity
|
Digital RH and NTC temperature
|
Digital RH and NTC temperature
|
Operating RH Range |
0 to 100% RH |
0 to 100% RH |
0 to 100% RH |
Operating Temperature |
-60°C to 140°C |
-40°C to 125°C |
-40°C to 125°C |
Unique Features |
- Robust and recognized component
- Suitable for most humidity applications
- Cost-effective solution
|
- Low power consumption
- Fast response time
- Very low-temperature coefficient
- I2C interface or PWM interface or SDM interface
|
- Low power consumption
- Fast response time
- Very low-temperature coefficient
- I2C interface or PWM interface or SDM interface
- Optimal filter
|
Accuracy |
180 pF, ±3 pF at 55% RH |
±3% RH at 25°C (10 to 95% RH) ±0.3°C at 25°C |
±3% RH at 25°C (10 to 95% RH) ±0.3°C at 25°C |
Dimensions (mm) |
10 x 10 x 19 |
3.0 x 3.0 x 1.0 |
3.0 x 3.0 x 1.0 |
Typical Applications |
Applications requiring a robust humidity sensor in the appliance, HVACR, consumer electronics, printing, meteorology |
Humidity and temperature plug and play transducers for OEM demanding applications in the appliance, printer, medical, HVACR |
Humidity and temperature plug and play transducers for OEM demanding applications appliance, printer, medical, HVACR |
Humidity and Temperature (NTC) Mini-Modules
Package |
Cost-effective, small size mini-module |
Cost-effective, small size mini-module |
Cost-effective, small size mini-module |
Type |
Analog voltage RH and NTC temperature |
Digital RH and NTC temperature |
Analog voltage RH and NTC temperature |
Operating RH Range |
0 to 100% RH |
0 to 100% RH |
0 to 100% RH |
Operating Temperature |
-40°C to 110°C |
-40°C to 110°C |
-40°C to 110°C |
Unique Features |
- PTFE filter (Optional)
- Electronics fully protected (5 V)
- Multiple connector choices (JST, Samtec board to board through hole)
- Based on HTU21
|
- PTFE filter (Optional)
- Electronics fully protected (5 V)
- Multiple connector choices (JST, Samtec board to board through hole)
- Based on HTU21
|
- Electronics fully protected with potting material (3.3 V or 5 V)
- Multiple connector choices (JST, Samtec board to board through-hole)
|
Accuracy |
±3% RH at 55% RH; ±0.25°C at 25°C |
±3% RH at 55% RH; ±0.25°C at 25°C |
±3% RH at 55% RH; ±0.25°C at 25°C |
Dimensions (mm) |
27 x 11.9 x YY (Depending on the connector, from 6 to 10.8 mm length) |
27 x 11.9 x YY (Depending on the connector, from 6 to 10.8 mm length) |
27 x 11.9 x 6.7 |
Typical Applications |
Humidity and temperature plug and play transducers for OEM demanding applications in HVACR, home appliance, printer and medical |
Humidity and temperature plug and play transducers for OEM demanding applications in HVACR, home appliance, printer and medical |
Humidity and temperature plug and play transducers for OEM applications in HVACR, appliance, printer and medical |
Humidity and Temperature (NTC) Probes
Package |
Probe, RH only |
Probe, RH only |
Probe, RH and temperature |
Type |
Cost effective analog voltage RH probe |
Dedicated to low RH accurate measurement |
Cost effective analog voltage RH |
Operating RH Range |
0 to 100% RH |
0 to 100% RH |
0 to 100% RH |
Operating Temperature |
-40°C to 60°C |
-40°C to 60°C |
-40°C to 60°C |
Unique Features |
- Electronics fully protected with potting material
- Optional wiring length and connectors
|
- Electronics fully protected with potting material
- Optional wiring length and connectors
|
- Electronics fully protected with potting material
- Optional wiring length and connectors
|
Accuracy |
±3% RH at 55% RH |
±3% RH at 55% RH |
±3% RH at 55% RH; ±0.25°C at 25°C |
Dimensions (mm) |
57 x 11 x 11 (Standard wire length of 200 mm) |
57 x 11.5 x 11.5 (Standard wire length of 200 mm) |
86 x 11.5 x 11.5 (Standard wire length of 200 mm) |
Typical Applications |
Medical, telecommunication cabinets, green houses, process control, industrial |
Medical, drying cabinets, low humidity, meteorology |
Hygrostat, data loggers, cabinets |
Humidity and Temperature (NTC) Sensors
Frequency Output Systems (Digital)
Package |
PCB for board to board |
Type |
Frequency output for RH, direct NTC for temperature |
Operating RH Range |
RH range: 0 to 100% RH |
Operating Temperature |
-40°C to 85°C |
Unique Features |
- Voltage supply from 3 to 8 VDC
- Through hole or SMD
- T and R available
|
Accuracy |
±3% RH at 55% RH; ±0.25°C at 25°C |
Dimensions (mm) |
12.5 x 18.5 x 11.2 |
Typical Applications |
HVACR, printer, cabin comfort, hygrostat |